No Current Sellers for Fluke 773
Sign Up/Login to get notified when someone has one for sale.
Sign Up/Login to get notified when someone has one for sale.
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
Taking mA measurements by removing a wire and breaking the loop
Calling the control room to isolate a loop Testing analog input/output on a console Troubleshooting devices with mA inputs and outputs Repairing intermittent or erratic 4-20 mA loops Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Here are some specific ways the Fluke 773 Clamp Meters will help you:
Milliamp Clamp Features Application How it saves time and money Measure mA signals for PLC and control system analog I/O without breaking the loop. Measures low level dc current Correlate process indication with real physical value Measure output signals from transmitters without breaking the loop Maintain and troubleshoot process and automation equipment without breaking the loop No disruption to the process Detachable clamp with extension cable Measurements in tight locations Enables measurements in difficult situations Source, simulate and measure mA signals in circuit (break the loop) Confirm non-contact measurement. ve the next tool in hand for troubleshooting (source simulate) Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurement Source and measure VDC Troubleshoot voltage input and output devices. Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders 4 to 20 mA In/out Dual channel mA source and measurement for troubleshooting Source 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals. 4 to 20 mA scaled output Scaled mA output provides a mA signal output representative of the measured mA value Connect a logging DMM and log the mA signal without breaking the loop Loop power supply Power a transmitter Substitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting. Dual backlit display with both mA measurement and percent of 4 to 20 mA span Clear measurement presentation Allows quick measurement evaluation Measurement Spotlight Illuminates hard to see wires in dark enclosures Measurement process is easier and quicker Measure up to 99.9 mA range non-contact Wide range of measurements Measures 10 to 50 mA signals in older control systems Automatic power off After 15 minutes and 2 minute automatic off for backlight and spotlight Saves battery life
The 773 mA Clamp Meter features: Best in class 0.2 % accuracy0.01 mA resolution and sensitivityMeasure 4 to 20 mA signals without breaking the loop Measure mA signals for PLC and control system analog I/ODual backlit display with both mA measurement and percent of 4 to 20 mA spanMeasurement Spotlight illuminates hard to see wires in dark enclosuresDetachable clamp with extension cable for measurements in tight locationsMeasure 10 to 50 mA signals in older control systems using the 99.9 mA rangeAutomatically change the 4 to 20 mA output for remote testingPower saving features, auto-off, backlight timeout extend battery lifeHold function captures and displays changing measurementsMeasure 4 to 20 mA signals with in-circuit measurementSimultaneous mA in-circuit measurement with 24V loop power for powering and testing transmittersSource 4 to 20 mA signals for testing control system I/O or I/PsmA output linear ramp or 25% step outputAutomatically change the 4 to 20 mA output for remote testingDC voltage measurement to verify 24V power supplies or voltage I/O signalsSource DC voltage to test input devices that accept a 1-5V or 0 to 10V signalsScaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clampEnables milliamp signal logging to a separate logging device without breaking the loopOutput mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loopmA in/out: simultaneously measure the mA signal with the clamp and source a mA signalApply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolatorsVoltage output linear ramp or 25% step outputAutomatically change the voltage output for remote testingWhat’s the difference between the 77X models?
.
Fluke-771
Fluke-772
Fluke-773 .
Non-contact mA loop measurement
Integrated mA loop troubleshooting
Advanced process troubleshootingmA measure, jaw
mA measure, in circuit
.
Loop power
.
mA source
.
DCV measure
.
.
DCV source
.
.
mA scaled output
.
.
mA in / out
.
.
There are no reviews for this product at the moment
No current Alternatives.
You may find Alternatives in category.