Tektronix DPO77002SX Performance Oscilloscopes

Product Details

  • Manufacturer: Tektronix

  • Model: DPO77002SX

  • Description:

    DPO70000SX provides ultra-high bandwidth real time signal acquisition and analysis up to 70 GHz analog bandwidth.

No Current Sellers for Tektronix DPO77002SX

Sign Up/Login to get notified when someone has one for sale.

The DPO70000SX 70 GHz oscilloscope provides the industry's lowest-noise real time acquisition using Tektronix patented Asynchronous Time Interleaving (ATI) technology. The series' compact and scalable package allows flexible system configurations. Get the most accurate real time performance for ultra-bandwidth applications like coherent optical, radar, high speed serial data communications, or leading-edge research.

Using ATI technology, the 70 GHz model delivers best-in-class signal capture. 
Compact, scalable, 5 1/4" package allows you to position units close to the device under test. 
UltraSync ensures precise data synchronization and convenient Master/Extension operation in multi-unit systems.

 

DPO77002SX KEY PERFORMANCE SPECIFICATIONS

70 GHz analog bandwidth, <6 ps rise time
Low-noise ATI architecture
Industry-leading sample rate and timing resolution
200 GS/s, 5 ps/Sample real-time sample rate

 

Features

Benefits

70 GHz Bandwidth
Preserve signal-to-noise ratio for higher fidelity using Tektronix__ patented Asynchronous Time Interleaving (ATI) technology with 70 GHz real-time bandwidth.  More accurately capture and measure your signals at higher signal speeds than possible with any other oscilloscope available today. Learn more about ATI _

200 GS/s Sample Rate
200 GS/s sample rate with 5 ps/sample resolution gives improved resolution and timing.

Lowest-noise, Highest Effective Number of Bits (ENOB)
Perform your tests with more available margin and trust that you are seeing your real signal to make more precise measurements.

UltraSync Architecture
Ensures precise data timing in a multi-unit system for acquisition-to-acquisition jitter
 

MODEL OVERVIEW
  DPO77002SX DPS77004SX DPO73304SX DPS73308SX
  Single unit Dual-unit system Single unit Dual-unit system
  ATI channel TekConnect channels ATI channel TekConnect channels TekConnect channels TekConnect channels
Analog channels/bandwidth 1/70 GHz (typical) 
1/67 GHz
2/33 GHz 2/70 GHz (typical) 
2/67 GHz
4/33 GHz 2/33GHz, 4/23GHz 4/33GHz, 8/23GHz 1
Sample rate per channel 200 GS/s 100 GS/s 200 GS/s 100 GS/s 2 ch 100 GS/s, 4 ch 50 GS/s 4 ch 100 GS/s, 8 ch 150 GS/s
Rise time (typical) 10% to 90%: 5.6 ps 20% to 80%: 4.3 ps 10% to 90%: 13 ps 20% to 80%: 9 ps 10% to 90%: 5.6 ps 20% to 80%: 4.3 ps 10% to 90%: 13 ps 20% to 80%: 9 ps 10% to 90%: 13 ps 20% to 80%: 9 ps 10% to 90%: 13 ps 20% to 80%: 9 ps
Vertical Noise (% of full scale), bandwidth filter on, max sample rate (typical) 0.75% of full scale (300 mVFS) 0.56% of full scale (500 mVFS) 0.75% of full scale (300 mVFS) 0.56% of full scale (500 mVFS) 0.56% of full scale (500 mVFS) 0.56% of full scale (500 mVFS)
Record length, points (each channel, standard) 62.5 M 62.5 M 62.5 M 62.5 M 62.5 M 62.5 M
Record length (each channel, Opt. 10XL) 125 M 125 M 125 M 125 M 125 M 125 M
Record length (each channel, Opt. 20XL) 250 M 250 M 250 M 250 M 250 M 250 M
Record length (each channel, Opt. 50XL) 1 G 1 G 1 G 1 G 1 G 1 G
Timing resolution 5 ps (200 GS/s) 10 ps (100 GS/s) 5 ps (200 GS/s) 10 ps (100 GS/s) 10 ps (100 GS/s) 10 ps (100 GS/s)
Duration at highest sample rate (Standard) 313 µs 625 µs 313 µs 625 µs 625 µs 625 µs
Duration at highest sample rate (Opt. 10XL) 625 µs 1.25 ms 625 µs 1.25 ms 1.25 ms 1.25 ms
Duration at highest sample rate (Opt. 20XL) 1.25 ms 2.5 ms 1.25 ms 2.5 ms 2.5 ms 2.5 ms
Duration at highest sample rate (Opt. 50XL) 5.0 ms 10 ms 5.0 ms 10 ms 10 ms 10 ms

 

Software Option

Description

TekScope Anywhere™

TekScope AnywhereTM brings the power of the scope analysis environment to the PC. Users now have the flexibility to perform analysis tasks including timing, eye, and jitter analysis outside the lab.

Opt. DJA

Simplifies identifying signal integrity concerns, jitter and their related sources and provides the highest sensitivity and accuracy available for real-time oscilloscopes.

Opt. SDLA64

Offers the capability to emulate the serial data channel, de-embed fixtures, cables, or probes, and add or remove equalization. Option SDLA64 also provides processing of waveforms with IBIS-AMI Receiver Equalization, or CTLE, FFE and/or DFE equalization. DPOJET provides advanced measurement and jitter analysis of the resulting waveforms.

Opt. SV23

WLAN 802.11a/b/g/j/p measurement application

Opt. SV24

WLAN 802.11n measurement application

Opt. SV25

WLAN 802.11ac measurement application

Opt. SV27

SignalVu Bluetooth Basic LE TX SIG measurements

Opt. SVA

SignalVu AM/FM/Direct Audio Measurements.

Opt. SVE

SignalVu wideband spectral analysis and measurements.

Opt. SVM

SignalVu General-purpose Modulation Analysis

Opt. SVP

 SignalVu Advanced Pulse Signal Analysis.

Opt. SVT

SignalVu Settling Time Measurements – Frequency and Phase.

Product Average Rating:
(0 reviews)


There are no reviews for this product at the moment


Your Review: Please log in to add a review.

No current Alternatives.
You may find Alternatives in category.

Advertisement