Hp/Agilent/Keysight 85070B High-Temperature Dielectric Probe Kit

Product Details

  • Manufacturer: Hp/Agilent/Keysight

  • Model: 85070B

  • Description:

    The Keysight 85070B dielectric probe is well-suited for measurements of liquid or semi-solid materials.

No Current Sellers for Hp/Agilent/Keysight 85070B

Sign Up/Login to get notified when someone has one for sale.

Measure the dielectric properties of materials quickly and conveniently with the Keysight 85070B dielectric probe. Measurements made with this probe are nondestructive and require no sample preparation - saving you time, trouble, and material.The dielectric probe is well-suited for measurements of liquid or semi-solid materials. Simply immerse the probe into the material there is no need for special fixtures. The Keysight 85070B dielectric probe yields permittivity (dielectric constant), loss factor, loss tangent, or Cole-Cole diagrams -versus frequency from 200 MHz to 20 GHz. Hermetic glass-to metal seal, which makes it resistant to corrosive or abrasive chemicalsWithstands a wide -40 C to +200 C temperature rangeA special refresh calibration simplifies measurements over temperatureer’, er", tan delta or Cole-Cole plots tabular listings of dataHardcopy plots to plotters or graphics printers tabular listing to printers save/recall/export data via disk in MS-DOS ASCII format or HP BASIC BDAT format (HP LIF binary)

Measure the dielectric properties of materials quickly and conveniently with the Keysight 85070B dielectric probe. Measurements made with this probe are nondestructive and require no sample preparation -- saving you time, trouble, and material.

The dielectric probe is well-suited for measurements of liquid or semi-solid materials. Simply immerse the probe into the material; there is no need for special fixtures. The Keysight 85070B dielectric probe yields permittivity (dielectric constant), loss factor, loss tangent, or Cole-Cole diagrams -versus frequency- from 200 MHz to 20 GHz.

  • Hermetic glass-to metal seal, which makes it resistant to corrosive or abrasive chemicals
  • Withstands a wide -40 °C to +200 °C temperature range
  • A special refresh calibration simplifies measurements over temperature
  • er', er", tan delta or Cole-Cole plots; tabular listings of data
  • Hardcopy plots to plotters or graphics printers; tabular listing to printers; save/recall/export data via disk in MS-DOS® ASCII format or HP BASIC BDAT format (HP LIF binary)

Product Average Rating:
(0 reviews)


There are no reviews for this product at the moment


Your Review: Please log in to add a review.