ROHDE & SCHWARZ NRT-Z, R&S NAP-Z Power Sensors

Product Details

  • Manufacturer: ROHDE & SCHWARZ

  • Model: NRT-Z,

  • Description:

    NRT-Z, NAP-Z Power Sensors – Power sensors for Power Reflection Meter R&S NRT

No Current Sellers for ROHDE & SCHWARZ NRT-Z,

Sign Up/Login to get notified when someone has one for sale.

Power Sensors R&S NRT-Z can be used as self-contained measuring instruments with digital interface even without the base unit. In addition to a directional coupler and analog section, they comprise a processor kernel for control of the hardware and remote interface and for processing the measured data (temperature compensation, linearization, zeroing and Frequency-response correction). The R&S NAP-Z power sensors are available for performing measurements in the Frequency range starting from 200 kHz or on powerful sources with a nominal power of up to 1 kW or 2 kW. The compact concept allows and ensures measurement functions without the restrictions of conventional analog solutions. Directional Power Sensors R&S NRT-ZPower Sensors NRT-Z can be used as self-contained measuring instruments with digital interface even without the basic unit. In addition to a directional coupler and analog section, they comprise a processor kernel for control of the hardware and remote interface and for processing the measured data (temperature compensation, linearization, zeroing and Frequency-response correction). This compact concept allows a ensures of measurement functions without the restrictions of conventional analog solutions. Average power (rms value)This measurement function returns for any type of test signal – whether modulated, unmodulated or several carriers – the average value of he power, ie a result as provided by a thermal power meter. It features a measurement range of 35 dB to 40 dB as well as high measurement accuracy. Peak envelope power (PEP)and crest factorThese two parameters provide information on the peak power of a modulated envelope and thus describe the overdrive characteristics of transmitter output stages.The result of the crest factor measurement is referred to the average power and read out in dB.The measurements are carried out with a video band width adjustable in several steps and allow determination even of short-time, high power peaks generated, for example, by CDMA base stations. Average burst powerThis function can be used for measuring modulated and unmodulated bursts.The measurement is based on the average power and the duty cycle,which may be defined by the user or determined automatically by the power sensor.Complementary cumulative distribution function (CCDF)This function measures he probability of the peak envelope power exceeding a preset threshold so that the amplitude distribution of transmitted signals with non-determined envelope can be determined.MatchingThe power sensor calculates the matching of he load from the average values of forward and reverse power.This parameter can be output in all common representations – as return loss, SWR, reflection coefficient or power ratio in %.Since the reverse power measurement channel is 10 dB more sensitive than the forward channel, matching measurements can already be made at very low powers. Excellent shieldingThe power sensors feature excellent shielding so that emissions from the microprocessor or from the digital data stream on the connecting cable are completely blocked out. Any radiated emissions at he RF connectors are below thelimit of detection. The excellent intermodulation characteristics keep unwanted Frequency components resulting from the insertion of the power sensor to a minimum. These are all good reasons to use NRT-Z sensors not only for esting but also in fixed installations. Direct power monitoring on PCThis is the most economical way of performing high-precision power and reflection measurements with Power Sensors NRT-Z. Via Interface Converters NRT-Z3 and NRT-Z4, the two sensors can be operated on the serial RS-232 or PC Card interface of any PC. In addition to purely remote-controlled applications, eg power monitoring in transmitter stations and EMC test systems, this solution is ideal where the data are to be collected by a computer. This may be in the development laboratory as well as in the maintenance of base stations, where in addition to power and reflection other parameters have to be measured and recorded. A Windows user interface (V-NRT,supplied with the sensors) is available for all these applications. This program allows setting of all the available measurement functions as well as display and storage both of individual results and of whole measurement series.

Low insertion loss
Very good matching
Excellent intermodulation characteristics
Direct power monitoring on PC

R&S NRT-Z, NAP-Z : Power Sensors
R&S NRT-Z43 : Directional Power Sensor
R&S NRT-Z44 : Directional Power Sensor
R&S NRT-Z14 : Directional Power Sensor
R&S NAP-Z6 : Directional Power Sensor
R&S NAP-Z7 : Directional Power Sensor
R&S NAP-Z8 : Directional Power Sensor
R&S NRT-Z3 : Interface Adapter
R&S NRT-Z5 : Interface Adapter
R&S NRT-Z2 : Extension Cable
R&S NAP-Z2 : Extension Cable

Product Average Rating:
(0 reviews)


There are no reviews for this product at the moment


Your Review: Please log in to add a review.

No current Alternatives.
You may find Alternatives in category.

Advertisement