No Current Sellers for Yokogawa MX100
Sign Up/Login to get notified when someone has one for sale.
Sign Up/Login to get notified when someone has one for sale.
MX100 Style S3 New!
30-ch input module
Windows Vista compatible
Alarm levels increased from 2 to 4
Multi-Channel Capability, High Isolation Voltage
Multi-Interval Measurement
Flexible System Configuration
Versatile PC-Based Software Options
Easy Software Setup
No Re-Wiring between Measurements
All-in-one “Quick Start Packages” with 10, 20, or 30 Channels
Features
High-Speed Multi-Channel Capability
The table below provides reference information on the maximum number of measurable channels in relevant measurement intervals (when using Yokogawa’s proprietary software):
The relationship between measurement intervals and the number of channels largely depends on the performance of the PC. The actual performance may differ from that shown in the table.<PC System Requirements>CPU: Pentium 4 3.2 GHz; Memory: 1 GB; OS: Windows 2000; Hard disk: 160 GBCommunication interface: Ethernet 100Base-TX
Multi-Interval Measurement
Three types of measurement intervals can be used in a single system in various combinations. Measurement intervals are specified for each module. It is also possible to set different types of input modules to the same measurement interval or to set the same type of input modules to different measurement intervals. Twelve measurement intervals are available as userselectable options: 10 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s and 60 s. Please note, however, that measurement intervals of 10/50 ms cannot be set to the Medium-speed Universal Input Module (MX110-UNV-M10). Examples of Setting Measurement Intervals
Multi-interval systems can be flexibly built for each module as shown in the figure below. Three colors are used to indicate the three types of measurement intervals.
Monitor Window Using Yokogawa’s Proprietary PC Software
The window shows measurement values by measurement intervals. Measurement can be performed while confirming rapidly-changing signals and slowly-changing signals simultaneously.
A: Measurement of sine waves at 0.5 Hz with a measurement interval of 100 msB: Measurement of sine waves at 8 Hz with a measurement interval of 10 msC: Measurement of sine waves at 1 Hz with a measurement interval of 50 ms
High Withstand Voltage (Reinforced Insulation)
Reinforced (double) insulation has been provided between the input terminals and the case to achieve a high withstand voltage of 600 Vrms/VDC (continuous). As shown below, each battery voltage can be measured even if the batteries are stacked to increase common-mode voltages.
Noise Rejection (MX110-UNV-H04)
MX input modules employ integrating A/D converters with superior noise rejection performance. In particular, the MX110-UNV-H04 Four-Channel High-Speed Universal Input Module incorporates an integrating A/D converter for each input channel, thereby exhibiting strong noise rejection performance in high-speed measurement. Moreover, the digital filtering function is effective on noises that cannot be fully rejected even with integrating A/D converters. Time constants can be selected from 5 to 100 measurement interval times. Therefore, filtering can be applied according to the noise to be rejected.
Example of Noise Rejection
When the noise source in the left figure was applied to the MX, the result in the right figure was obtained. High-speed measurement can be stably performed even in noisy environments.
Noise source applied to the MXA noise signal was applied betweenH and L (in normal mode).
Output window of MX100 for noise inputsModule used: MX110-UNV-H04 Four-Channel High-Speed Universal Input ModuleMeasurement with the range of 2 V (-2 V to +2 V), measurement interval of 50 ms, integral time “Auto” and filter “OFF.”Example of noise rejection
System Configuration
Connection between a single MX unit and a single PC (measurement of 24 channels/10 ms or 60 channels/100 ms)
One MX unit enables data acquisition on up to 24 channels at a measurement interval of 10 ms, or up to 60 channels at a measurement interval of 100 ms (six modules installed in both cases).
Setting up the SystemThe MX and PC are connected via a hub and a straight Ethernet cable. Alternatively, they can be connected using a cross cable alone, without using the hub
Input signal: DC voltageThermocuple, RTD,Digital input (Mixed input possible)
PC SoftwareIn a one-to-one connection, the MX100 standard software included with the main module facilitates easy building of data acquisition environments.One MX unit consists of a combination of a main module, input/output modules, and a base plate. This configuration centers on the main module.
Output signal: Digital output
Connection between multiple MX units and a single PC
For measurement of up to 1,200 channels and the use of MXLOGGER
Example of a system with multiple MX units:
Setting up the SystemThe MX units and the PC are connected by means of a hub and straight Ethernet cables.PC SoftwareAcquisition of data from multiple MX units is well-supported by Yokogawa’s software “MXLOGGER” (optional). MXLOGGER enables data acquisitions of up to 20 MX units (one unit has inputs of up to 60 channels, or 1,200 channels on 20 units).Please note that the shortest measurement interval of MXLOGGER depends on the system’s total number of channels and the PC’s performance. For guidelines on measurement intervals and the number of channels, please visit….If users wish to create their own data acquisition software, there is no limit to the number of MX units that can be integrated with a single PC software element. Please note, however, that if conditions with heavy loads (such as short measurement intervals with many units) are set to the PC and its software, data will not be acquired in time and some data may be lost.
Hardware Configuration
ModuleThe MX is designed to enable desired measurement environments by combining three elements: the main module, input/output modules, and a base plate.The assembled unit can be utilized on the desktop as-is (the modules have legs). Please note that DIN rails are used for rack-mounting.
Main Module (MX100)
The main module is the engine that controls data acquisition. It is equipped with a power supply, an Ethernet port, and a CompactFlash card slot. One main module can accommodate up to six input/output modules. The user can choose up to six moduels of any type.
Ethernet port:For communication with the PC. Automatic recognition of 100Base-TX or 10Base-TCF (CompactFlash) Card Slot:With the CF Card, measured data is saved to the card if communication with the PC is interrupted. Since the card provides data backup, you do not have to worry about the possible loss of data even if the MX is configured for PC-based measurement.
Data Backup Time by CF Card Size(Note: Minutes/hours/days are approximate.)
Number of saved channels
Measurement interval
32 M
128 M
512 M
10 channels
10 ms
2 hours
9 hours
36 hours
100 ms
21 hours
3.5 days
15 days
500 ms
4.5 days
18.5 days
75.5 days
2 s
18 days
75.5 days
303 days
24 channels
10 ms
54 minutes
3.5 hours
15 hours
100 ms
9 hours
37 hours
6 days
500 ms
45 hours
7.5 days
31.5 days
2 s
7.5 days
31.5 days
126 days
60 channels
10 ms
18 minutes
75 minutes
5 hours
100 ms
3.5 hours
15 hours
2.5 days
500 ms
18 hours
3 days
12.5 days
2 s
3 days
12.5 days
50 days
Input Modules
Name
Model
Number of channels
Shortest measurement interval
Description
30 ch general purpose input module with 500 ms scan speed
MX110-VTDL30
30
500 ms
Clamp terminal, DCV/TC/DI
MX110-VTDL30/H3
30
500 ms
M3 screw terminal, DCV/TC/DI
Name
Model
Number of channels
Shortest measurement interval
Description
Universal Input Modules
MX110-UNV-H04
4
10 ms
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
MX110-UNV-M10
10
100 ms
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
4-Wire RTD and Resistance Input Module
MX110-V4R-M06
6
100 ms
DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
Strain Input Modules
MX112-B12-M04
4
100 ms
Built-in bridge resistance of 120 ohm
MX112-B35-M04
Built-in bridge resistance of 350 ohm
MX112-NDI-M04
For connection with an external bridge head and strain gauge type sensor (NDIS connector))
5 V Digital Input Module
MX115-D05-H10
10
10 ms
Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed.
24 V Digital Input Module
MX115-D24-H10
10
10 ms
Level (24 V logic), Vth = 12 V
Output Modules
Name
Model
Number of channels
Ouput update interval
Description
Analog Output Module
MX120-VAO-M08
8
100 ms
Allows mixed voltage (±10 V) and current (4-20 mA) output
PWM Output Module
MX120-PWM-M08
8
100 ms
Pulse width modulation output module
Digital Output Module
MX125-MKC-M10
10
100 ms
“A” contact (SPST)
Base Plate
Base plates available for all configurations, from 1 to 6 input/output modules.
When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.
Accessories
Connector CoversConnector covers for open slots AC Adapter (772075)AC adapter for the DC power model.Operating temperature range: 0 to 40°*Only for the MW100
Accessories (Removable Terminal)
All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements.
Model
Description
772061
Screw (M4) terminal block (RJC (reference junction compensation) included). For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772062
Connection cable between input modules and the screw terminal block. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772063
Plate with clamp terminals (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772064
Clamp terminals. Compatible with MX110-UNV-H04.
772065
Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10.
772067
Plate with clamp terminals. Compatible with MX110-V4R-M06.
772068
Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04.
772069
Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04.
772080
Plate with screw (M3) terminal (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772081
Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10
772082
Plate with clamp terminal for current with 100 ohm built in bridge resistance, applies to MX110-UNV-M10
772083
Plate with clamp terminal for current with 250 ohm built in bridge resistance, applies to MX110-UNV-M10
Mounting on Racks or Panels Using the DIN Rail
Use the DIN rail for mounting on on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).
Use the DIN rail for mounting on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).
There are no reviews for this product at the moment
No current Alternatives.
You may find Alternatives in category.