Fluke 5430-1 Standard AC/DC Resistors

Product Details

  • Manufacturer: Fluke

  • Model: 5430-1

  • Description:

    Fluke Standard AC/DC Resistor AC/DC Standard 1 ohm

     

No Current Sellers for Fluke 5430-1

Sign Up/Login to get notified when someone has one for sale.

Six resistors in Fluke Calibration's Model 5430 series cover resistance values from 1 ohm to 10,000 ohms. Each one has an actual resistance within 10 ppm of its nominal value and holds its resistance within 2 ppm per year.

Each resistor comes with a Tinsley certificate on AC performance, traceable to NPL, including calibration uncertainty of 3 ppm. Additionally, Fluke Calibration can provide an optional DC certificate, traceable to NIST and NVLAP accredited, with uncertainty below 1 ppm.

Designed originally by a national lab, Tinsley resistors are bifilar wound to minimize reactance and are filled with oil to minimize both time- and temperature-caused instabilities. AC/DC transfer error at 90 Hz is only 0.1 ppm.

For maintaining your oil resistors, Fluke Calibration provides baths that range from 25- to 155-liter capacity with enough inside shelf space to maintain all your standard resistors. Each of these baths maintains your resistors within 1 mK in the short term (30–60 minutes) and within 5 mK for months at a time.

 

Specifications

Tolerance 10 ppm
Calibration Uncertainty AC: 3 ppm (10 kΩ: 4 ppm) DC: 1 ppm (optional)
Long-Term Stability 2 ppm per year
Temperature Coefficient 2 ppm per °C
Recommended Current
 
 
 
 
 
1Ω: 100 mA
10Ω: 32 mA
25Ω: 20 mA
100Ω: 10 mA
1 kΩ: 3 mA
10 kΩ: 1 mA
Maximum Current
 
 
 
 
 
1Ω: 1 A
10Ω: 320 mA
25Ω: 200 mA
100Ω: 100 mA
1 kΩ: 32 mA
10 kΩ: 10 ma
AC/DC Transfer Error (at 90 hz) 0.1 ppm, typical

Product Average Rating:
(0 reviews)


There are no reviews for this product at the moment


Your Review: Please log in to add a review.

No current Alternatives.
You may find Alternatives in category.

Advertisement