Anritsu BERTWave MP2100A

Product Details

  • Manufacturer: Anritsu

  • Model: MP2100A

  • Description:

    The MP2100A is an all-in-one BERT and EYE/Pulse Scope solution for evaluating optical active devices in optical communication systems.

No Current Sellers for Anritsu MP2100A

Sign Up/Login to get notified when someone has one for sale.

The MP2100A is an all-in-one BERT and Eye/Pulse Scope solution for evaluating optical active devices in optical communication systems.To meet the need for the fastest possible measurement speeds on production lines for active optical devices, the Gating Time has been slashed by 90% compared to conventional BERT equipment using remote commands and the Eye/Pulse Scope function is 300% faster. In addition, measurement times are much shorter due to the simultaneous BER measurement and Eye pattern analysis.
The MX210001A Jitter Analysis Software has a new, high-speed, jitter-measurement function supporting all-in-one measurements, such as simultaneous jitter analysis, and Eye pattern measurement and Eye mask test measurements. Moreover, the high-speed sampling increases measurement efficiency by cutting measurement time.
And Combining the MX210001A with MATLAB supports WDP, TWDP and dWDP measurements for evaluating the waveform dispersion of specific signals.
Adding the MX210002A Transmission Analysis Software to the BERTWave supports Tx analyses (S21 Gain, Phase), and waveform simulation (de-embedded) using linear equalizer, filter, and emphasis operations; simultaneous waveform sampling and simulation support simultaneous Eye pattern measurement and Eye mask test measurements. Furthermore, combined tracking with the MX210001A software permits simultaneous post-simulation waveform jitter measurement.
MATLAB is a trademark of The MathWorks Inc.

Look at this comparison.All-in-one PPG, ED, Scope, and Optical IF for incredible, space-saving compactness


Click here for details about the BERTWAVE PE supporting BER measurements.


Click here for details about the BERTWAVE SS supporting EYE/Pulse Scope measurements.

BERTS

Operation bit rate

With MP2100A/MP2101A-090
Without MP2100A/MP2101A-090

PPG, ED Common; Variable bit-rate range (1 kbit/s step) 8 Gbit/s to 12.5 Gbit/s 1/N bit-rate operation range N=2: 4 Gbit/s to 6.25 Gbit/s N=4: 2 Gbit/s to 3.125 Gbit/s N=8: 1 Gbit/s to 1.5625 Gbit/s N=16: 500 Mbit/s to 781.25 Mbit/s N=32: 250 Mbit/s to 390.625 Mbit/s N=64: 125 Mbit/s to 195.312 Mbit/s PPG; Variable bit-rate range (1 kbit/s step) 8.5 Gbit/s to 11.32 Gbit/s 1/N bit-rate operation range N=2: 4.25 Gbit/s to 5.66 Gbit/s N=4: 2.125 Gbit/s to 2.83 Gbit/s N=8: 1.0625 Gbit/s to 1.415 Gbit/s N=16: 531.25 Mbit/s to 701.5 Mbit/s N=32: 265.625 Mbit/s to 353.75 Mbit/s N=64: 132.813 Mbit/s to 176.875 Mbit/s ED; Variable bit-rate range (1 kbit/s step) 8.5 Gbit/s to 11.32 Gbit/s 4.25 Gbit/s to 5.66 Gbit/s Test Pattern PRBS: 27-1, 29-1, 215-1, 223-1, 231-1, (Invert ON/OFF), USER Data: 1.3 Mbit programmable (sample pattern file such as CJPAT and so on) Electrical Data Output Data, Xdata Amplitude 0.1 Vp-p to 0.8 Vp-p Electrical Data Input Data, Xdata (Option 001), Data (Option 003) Amplitude 0.1 Vp-p to 0.8 Vp-p O/E Input (Option 003) Optical Data Wavelength Range 750 nm to 1650 nm XFP Slot (Option 050) XFP Slot SFP+ Slot (Option 051) SFP+ Slot

EYE/Pulse Scope

Bandwidth (-3 dB) DC to 20 GHz minimum, DC to 25 GHz Typical Display Eye Pattern, Pulse Pattern Measurement Function Statistical (NRZ), Histogram, Mask Compliance Sampling Speed 100 K samples/sec, Typical O/E Input (Option 003) Optical Data Wavelength Range 750 nm to 1650 nm Clock Recovery (Option 055) 0.1 GHz to 2.7 GHz, 8.5 GHz to 12.5 GHz

MX210001A Jitter Analysis Software

Operating Conditions Operates only when installed in MP2100A/MP2102A with correct license information The installer runs with V3.00.00 or later Other use conditions comply with MP2100A series The WDP runs under MATLAB R2010b SP1 Measurement Algorithm Histogram mode, Pattern Search mode Histogram mode Measurement Items TJ (1.0E-12), TJ (user defined), RJ (d-d), DJ (d-d), DDPWS, J2 jitter analysis, J9 jitter analysis, Eye opening Pattern Search mode Measurement Items TJ (1.0e-12), TJ (user defined), RJ (d-d), RJ (rms), DJ (d-d), PJ (p-p), DDJ (p-p), DCD, ISI (p-p), Eye opening, J2 jitter analysis, J9 jitter analysis, DDPWS, PJ Frequency WDP Measurement Requires installation of MATLAB 2010b by MathWorks Measurement Items WDP, dWDP, TWDP, dTWDP, WDPc, dWDPc, TWDPc, dWDPc

MX210002A Transmission Analysis Software

Operating Conditions Operates only when installed in MP2100A with correct license information The installer runs with V3.00.00 or later Other use conditions comply with MP2100A series Measurement Mode Transmission analysis, Waveform estimation Transmission Analysis Measurement Items Gain graph, Phase graph, Group delay graph (Phase graph and Group delay graph switching display) Waveform Estimation Equalizer Setting Selects reflector, non-reflector at calculation Emphasis Format 2Post/1Pre, 3Post, 1Post/1Pre, 2Post, 1Post Device Character Reads S2P File Jitter Analysis Displays estimated waveform calculation results at MX210001A (when MX210001A installed in MP2100A)