AC voltage (True-rms) |
Range: |
0 to 600.0 V |
0 to 1000.0 V |
Accuracy: |
±1.0% + 5LSD (50 to 60 Hz) |
±0.8% + 5LSD (50 to 60 Hz) |
DC voltage |
Range: |
0 to 600.0 V |
Accuracy: |
±1.0% + 5LSD |
AC+DC voltage |
Range: |
– |
0 to 600.0 V |
– |
0 to 600.0 V |
0 to 1000.0 V |
Accuracy: |
– |
±1.2% + 7LSD (50 to 60 Hz) |
– |
±1.2% + 7LSD (50 to 60 Hz) |
±1.0% + 7LSD (50 to 60 Hz)
±1.8% + 7LSD (DC 40 to 200 Hz)
±1.2% + 7LSD 200 to 400 Hz) |
AC current |
Range: |
0 to 600.0 A |
Accuracy: |
±1.8% + 5LSD (50 to 60 Hz)
±2.0% + 5LSD (100 to 400 Hz) |
DC current |
Range: |
– |
0 to 600.0 A |
– |
0 to 600.0 A |
0 to 1000.0 A |
Accuracy: |
– |
±2.0% + 5LSD (DC 50 to 100 Hz) |
– |
±2.0% + 5LSD (DC 50 to 100 Hz) |
±1.8% + 5LSD (DC 50 to 100 Hz) |
AC+DC current |
Range: |
– |
0 to 600.0 A |
– |
0 to 600.0 A |
0 to 1000.0 A |
Accuracy: |
– |
±2.2% + 7LSD (DC 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz) |
– |
±2.2% + 7LSD (DC 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz) |
±2.2% + 7LSD (40 to 100 Hz)
±2.5% + 7LSD (100 to 400 Hz) |
Precise low current AC |
Range: |
0 to 60.00 A |
Accuracy: |
±1.5% + 5LSD (50 to 60 Hz) |
±1.5% + 5LSD (50 to 60 Hz)
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz)
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz) |
Precise low current DC |
Range: |
– |
0 to 60.0 A |
– |
0 to 60.0 A |
0 to 60.00 A |
Accuracy: |
– |
±2.0% + 5LSD |
– |
±2.0% + 5LSD |
±1.5% + 5LSD (0.00 to 20.00 A)
±3.0% + 5LSD (>20.00 to 60.00 A) |
Micro amps |
Range: |
– |
– |
0 to 2000 µA |
Accuracy: |
– |
– |
±1.0% + 5LSD |
Frequency |
Range: |
5.00 to 999.9 Hz |
Accuracy: |
±1.0% + 5LSD (600 V range) |
Range: |
50.0 to 400.0 Hz |
Accuracy: |
±2.0% + 4LSD (600 A range) |
Resistance |
Range: |
0.0 to 60.00 kΩ |
Accuracy: |
±1.0% + 5LSD |
Capacitance |
Range: |
0.0 to 2500 µF |
Accuracy: |
±2.0% + 4LSD |
Continuity beeper |
ON ≤ 10 Ω |
Off > 250 Ω |
Temperature*
(Type K thermocouple) |
|
– |
– |
-40.0 to 752 °F
-40.0 to 400 °C |
|
– |
– |
±1.0% + 3.0 °F (-40.0 to 14.0 °F)
±1.0% + 1.5 °F (>40.0 to 99.9 °F)
±1.0% + 2.0 °F (100 to 752 °F)
±1.0% + 1.5 °C (-40.0 to 10.0 °C)
±1.0% + 0.8 °C (>-10.0 to 99.9 °C)
±1.0% + 1.0 °C (100 to 400 °C) |
Non-contact voltage |
10 V to 1000 V AC (50 to 60 Hz) |
Phase rotation indication |
|
– |
– |
Rotation-R for main supply
Rotation-M for motors |
Diode test |
|
• |
• |
• |
• |
• |
Jaw opening |
|
1.18 in (30 mm) |
1.37 in (35 mm) |
1.18 in (30 mm) |
1.37 in (35 mm) |
2.0 in (51 mm) |
Safty rating |
|
CAT III 600 V |
CAT IV 600V
CAT III 1000 V |
In-rush current |
|
– |
• |
• |
• |
• |
Peak hold (Crest) |
|
– |
– |
– |
– |
• |
Relative zero |
|
• |
• |
• |
• |
• |
Max/Min/Avg |
|
• |
• |
• |
• |
• |
Data hold |
|
• |
• |
• |
• |
• |
Backlight |
|
• |
• |
• |
• |
• |
Auto power off |
|
• |
• |
• |
• |
• |
Work light |
|
– |
– |
– |
– |
• |
*Error does not include Type-K thermocouple errors
For complete specs please download the product datasheet under the "Resources" tab.
|
|
|
|