Yokogawa Insulation tester 3213-44

Product Details

  • Manufacturer: Yokogawa

  • Model: 321344

  • Description:

    Rating 500V/1000M_; Effective Measuring Range 1_1000M_; Central Scale Value 20M_; AC Voltage Measurement 0 to 300 V; Lower Limit 0.5M_; Rated Current 1 mA

No Current Sellers for Yokogawa 321344

Sign Up/Login to get notified when someone has one for sale.

Analog models with single rating
AC voltage measurement and check live lines such as motive power lines
One-touch operation Press-and-lock switch for continuous measurement
A wide choice of accessories to meet various testing requirements
Vibration – and shock-resistant hand-held compact testers
Approx weight including batteries, or Approx. weigh including hard case, handle, test leads and batteries

Specifications – Model 321341

Rating
100V/20M_

Effective Measuring Range
0.02–20M_

Central Scale Value
0.5M_

AC Voltage Measurement
0 to 150 V

Lower Limit
0.1M_

Rated Current
1 mA

Scale Length
88 mm

Approx. Width
110 mm

Approx. Height
180 mm

Approx. Depth
60 mm

Approx. Weight
700 g 1.2 kg

Batteries
Eight AA (R6P) batteries

Standard Accessories
Batteries Qty – 8 Handle (B9303XE) Qty – 1 Hard case (B9600HA) Qty – 1 (with leads-housing case) Test lead (B9205VA) Qty – 1 (consist of earth/line terminal) User’s manual Qty – 1

Standard Test Conditions – Model 321341

Ambient Temperature/Humidity Ranges
23 ±5 /45-75% RH

Position of Use
Horizontal (5° max. of angle of inclination)

Battery Voltage
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications – Model 321342

Rating
250V/50M_

Effective Measuring Range
0.05–50M_

Central Scale Value
1M_

AC Voltage Measurement
0 to 250 V

Lower Limit
0.25M_

Rated Current
1 mA

Scale Length
88 mm

Approx. Width
110 mm

Approx. Height
180 mm

Approx. Depth
60 mm

Approx. Weight
700 g 1.2 kg

Batteries
Eight AA (R6P) batteries

Standard Accessories
Batteries Qty – 8 Handle (B9303XE) Qty – 1 Hard case (B9600HA) Qty – 1 (with leads-housing case) Test lead (B9205VA) Qty – 1 (consist of earth/line terminal) User’s manual Qty – 1

Standard Test Conditions – Model 321342

Ambient Temperature/Humidity Ranges
23 ±5 /45-75% RH

Position of Use
Horizontal (5° max. of angle of inclination)

Battery Voltage
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications – Model 321343

Rating
500V/100M_

Effective Measuring Range
0.1–100M_

Central Scale Value
2M_

AC Voltage Measurement
0 to 300 V

Lower Limit
0.5M_

Rated Current
1 mA

Scale Length
88 mm

Approx. Width
110 mm

Approx. Height
180 mm

Approx. Depth
60 mm

Approx. Weight
700 g 1.2 kg

Batteries
Eight AA (R6P) batteries

Standard Accessories
Batteries Qty – 8 Handle (B9303XE) Qty – 1 Hard case (B9600HA) Qty – 1 (with leads-housing case) Test lead (B9205VA) Qty – 1 (consist of earth/line terminal) User’s manual Qty – 1

Standard Test Conditions – Model 312343

Ambient Temperature/Humidity Ranges
23 ±5 /45-75% RH

Position of Use
Horizontal (5° max. of angle of inclination)

Battery Voltage
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications – Model 321344

Rating
500V/1000M_

Effective Measuring Range
1–1000M_

Central Scale Value
20M_

AC Voltage Measurement
0 to 300 V

Lower Limit
0.5M_

Rated Current
1 mA

Scale Length
88 mm

Approx. Width
110 mm

Approx. Height
180 mm

Approx. Depth
60 mm

Approx. Weight
700 g 1.2 kg

Batteries
Eight AA (R6P) batteries

Standard Accessories
Batteries Qty – 8 Handle (B9303XE) Qty – 1 Hard case (B9600HA) Qty – 1 (with leads-housing case) Test lead (B9205VA) Qty – 1 (consist of earth/line terminal) User’s manual Qty – 1

Standard Test Conditions – Model 321344

Ambient Temperature/Humidity Ranges
23 ±5 /45-75% RH

Position of Use
Horizontal (5° max. of angle of inclination)

Battery Voltage
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications – Model 321345

Rating
1000V/2000M_

Effective Measuring Range
2–2000M_

Central Scale Value
50M_

AC Voltage Measurement
0 to 300 V

Lower Limit
1M_

Rated Current
1 mA

Scale Length
88 mm

Approx. Width
110 mm

Approx. Height
180 mm

Approx. Depth
60 mm

Approx. Weight
700 g 1.2 kg

Batteries
Eight AA (R6P) batteries

Standard Accessories
Batteries Qty – 8 Handle (B9303XE) Qty – 1 Hard case (B9600HA) Qty – 1 (with leads-housing case) Test lead (B9205VA) Qty – 1 (consist of earth/line terminal) User’s manual Qty – 1

Standard Test Conditions – Model 321345

Ambient Temperature/Humidity Ranges
23 ±5 /45-75% RH

Position of Use
Horizontal (5° max. of angle of inclination)

Battery Voltage
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.