M9100 Multi Solar Battery Test System, as a simple operation and practical control software developed by Maynuo Electronic Co., Ltd., is applicable for multi-set of M97 series electronic load of our company to test for multi-channel solar battery in parallel. By this software, our users can not only track the maximum power (Pmax) accurately, but also save in real time and export the test data to Excel sheet. It is really a professional software for solar battery test and data analysis. The growth of the solar energy industry increases the needs for test solutions about the solar battery (and solar module). Besides, with the increasement of battery size and improvement of solar battery working efficiancy, battery test requires a kind of equipment which can provide bigger current and higher power. Our M97 series electronic load is complete in model, with power ranging from 150W to 200KW and current ranging from 15A to 1500A, which can defintely meet solar battery’s (and solar module) requirements for power and current. Generally the following key parameters of solar battery need to be tested:
Vopen—— Open-circuit voltage, is the battery voltage when the battery current is 0.
Ishort—— Short-circuit current, is the current drawn from the battery when the resistance of electronic load is 0.
Pmax—— The maximum power of the battery. The Pmax point in I-V curve is usually called the maximum power point.
Ipmax—— The current value when battery is in the maximum power Pmax.
Vpmax—— The voltage value when battery is in the maximum power Pmax.
Rpmax—- The resistance value when battery is in the maximum power Pmax.
FF—— Fill factor, is the ratio of Pmax to the Vopen and Ishort, that is, Pmax/(Vopen*Ishort). FF is an important parameter which effects directly the solar battery performance. The bigger the FF value is, the higher utilization of solar battery to light is.
Rs—— The series resistance of the battery.
Rsh—— The shunt resistance of the battery.
M97 series electronic loads can work in constant voltage mode which is also known as CV mode. When in CV mode, the electronic load can control the voltage across battery to a constant voltage by adjusting the current flowing through itself, so CV mode can be applied to the voltage scanning. In each step scanning, electronic load can control the output voltage of solar battery and then measure the current it generated. So we can see that CV mode is the best mode for solar battery test. Of course, you can aslo use CC/CR/CW mode according to your test requirements.
Vopen—— Open-circuit voltage, is the battery voltage when the battery current is 0.
Ishort—— Short-circuit current, is the current drawn from the battery when the resistance of electronic load is 0.
Pmax—— The maximum power of the battery. The Pmax point in I-V curve is usually called the maximum power point.
Ipmax—— The current value when battery is in the maximum power Pmax
Vpmax—— The voltage value when battery is in the maximum power Pmax
Rpmax—- The resistance value when battery is in the maximum power Pmax
FF—— Fill factor, is the ratio of Pmax to the Vopen and Ishort, that is, Pmax/(Vopen*Ishort). FF is an important parameter which effects directly the solar battery performance. The bigger the FF value is, the higher utilization of solar battery to light is.
Rs——The series resistance of the battery.
Rsh——The shunt resistance of the battery.