Key Features & Specifications
Output ratings (4 outputs)
- Low-range volts, amps 50W: 0 to 16 V, 0 to 200 mA
- High range volts, amps 50W: 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A
Programming accuracy at 25°C ±5°C (4 outputs each)
- Voltage 50W: 0.016% + 3 mV (low), 10 mV (high)
- Current 50W: 0.04% + 185 µA (low), 500 µA (high)
Ripple & noise (20 Hz to 20 MHz) 4 outputs each
- Voltage rms: 500 µV
- Peak-to-peak: 3 mV
- Current rms: 0.1 mA
Description
Agilent high performance DC power supplies offer spec and accuracy for test optimization. The precision multiple output, 25W - 50W GPIB 6625A, 6626A, 6628A, and 6629A provide fast, low-noise outputs; dual-range, precision low current measurement; built-in measurements and advanced programmable features; and protection features to ensure DUT safety.
The Agilent 50W, four-output 6629A is a versatile solution to help improve system accuracy and reduce test time in a 3U high package.
Specifications
Specifications
(at 0 ° to 55 °C unless otherwise specified) 25 W output 50 W output
Output power
Low-range voltage, current 0 to 7 V, 0 to 16 V,
0 to 15 mA 0 to 200 mA
High range voltage, current 0 to 50 V, 0 to 50 V, 0 to 1 A or
0 to 500 mA 0 to 16 V, 0 to 2 A
Output combinations
for each model (total number of outputs)
6625A (2) precision 1 1
6626A (4) precision 2 2
6628A (2) precision — 2
6629A (4) precision — 4
Programming accuracy at 25 °C ± 5 °C
Voltage (low) 0.016% + 1.5 mV 3 mV
(high) 0.016% + 10 mV 10 mV
Current (low) 0.04% + 15 μA 185 μA
(high) 0.04% + 100 μA 500 μA
Readback accuracy at 25 °C ± 5 °C
Voltage (low) 0.016% + 2 mV 3.5 mV
(high) 0.016% + 10 mV 10 mV
± Current (low) 0.03% + 15 μA 250 μA
(high) 0.03% + 130 μA 550 μA
Ripple and noise
(peak-to-peak, 20 Hz to 20 MHz;
rms, 20 Hz to 10 MHz)
Constant voltage rms 500 μV 500 μV
peak-to-peak 3 mV 3 mV
Constant current rms 0.1 mA 0.1 mA
Load regulation
Voltage 0.5 mV 0.5 mV
Current 0.005 mA 0.01 mA
Load cross regulation
Voltage 0.25 mV 0.25 mV
Current 0.005 mA 0.01 mA
Line regulation
Voltage 0.5 mV 0.5 mV
Current 0.005 mA 0.01 mA
Transient response time
Less than 75 μs for the output voltage to recover to within 75 mV of nominal value
following a load change within specifications
Supplemental characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
25 W output 50 W output
Average programming resolution
Voltage (low) 460 μV 1 mV
(high) 3.2 mV 3.2 mV
Current (low) 1 μA 13 μA
(high) 33 μA 131 μA
OVP 230 mV 230 mV
Output programming response time 6 ms 6 ms
Shipping and handling
Item location United States
Worldwide
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
NA | NA | USPS Priority Mail Express International |
Domestic
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
$150.00 | NA | United States | Economy Shipping |
Return policy
After receiving the item, connect seller within | Refund will be given as | Return shipping |
---|---|---|
14 Days | Money Back | Buyer pays return shipping |
Payment options
Options: NA