DIVIDE BY 100 AND DIVIDE BY 1000 SWITCH SETTINGS, 100 MHZ, 1400V
The 4234 meets EN61010 Category III Requirements. With wide choice of
attenuation ratio, the 4234 is capable of making full range (from millivolts to ±1400V)
measurements of floating signals in power electronic circuits.
Features
-Bandwidth up to 100 MHz
-Up to +/-1400V(DC+Peak AC) Differential and Common Mode
-Safety Certified Applications
-Switching Power Supply Design
-Motor Drive Design
-Electronic Ballast Design
-CRT Display Design
Included
-Black Storage Box
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9 VDC Adapter
Model 4234 Specifications
Bandwidth | DC-100MHz (-3dB) |
Attenuation | 1/100 and 1/1000 (switchable) |
Rise Time | 3.5 ns |
Accuracy | +/- 2% |
Input Impedance | 4 M Ohm //7pF each side to ground |
Input Voltage -Catagory -Differential Range -Common Mode Range -Absolute Max. Voltage(Differential Or Common Mode) |
CAT III 140 Vrms and +/-140V(DC +Peak AC) @ 1/100 1000Vrms and +/-1400V(DC + Peak AC @1/1000 1000Vrms and +/-1400V(DC + Peak AC)@1/100 & 1/1000 1000Vrms and +/-1400V(DC +Peak AC)@1/100 & 1/1000 |
Output Voltage -Swing -Offset (typical) -Noise(typical) -Source Impedance (typical) |
+/-7V (into 50kohm load) <+5mV 0.9m Vrms 50 Ohm( for using 1 Mohm input system oscilloscope) |
CMMR (typical) | -80dB @650Hz, -50dB @ 1 MHz |
Ambient Operating temperature | -10 to 40 degree centigrade |
Ambient Storage Temperature | -30 to 70 degree centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Length of Input Leads | 12" |
Length of BNC Cable | 37" |
Power Requirements* | Standard 4 x AA cells or 9VDC Adapter (Both Included) Options-Power Leads |
Weight | 0.9 lb |
Dimensions | (LxWxH) 8" x 3 1/4" x 1 1/2" |
Voltage limit is the lesser of the DC+Peak AC and RMS values 1000Vrms and + 1400V(DC + Peak AC) @1/100 & 1/1000
* a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe could be damaged or can¡¦t be operated properly.
b. polarity is "+" inside and "¡V" outside. For wrong polarity, built-in circuit protects the probe, no danger or damage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel will flicker.
Shipping and handling
Item location United States
Worldwide
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
$220.00 | NA | Expedited International Shipping |
Domestic
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
$30.00 | NA | United States | Economy Shipping |
Return policy
After receiving the item, connect seller within | Refund will be given as | Return shipping |
---|---|---|
14 Days | Money Back | Buyer pays return shipping |
Payment options
Options: NA