The 4232 is designed to safely analyze floating signals. The built in amplifier scales and converts the high voltage differential
input to a low, voltage single-ended BNC output, compatible with any oscilloscope. The inputs are useful in
measurements of power semiconductor circuits, robotic drives, NC machines and the latest switching circuits.
Applications
-Switching Power Supply Design
-Motor Drive Design
-Electronic Ballast Design
-CRT Display Design
Features
-Up to +/-1400V (DC +Peak AC) Differential and Common Mode
-Safety Certified
-Economical cost
Cost Included
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9VDC Adapter
Model 4232 Specifications
Bandwidth | DC to 25 MHz (-3dB) |
Attenuation Ratio | 1/10 & 1/100 |
Accuracy | +/- 2% |
Rise Time | 14ns |
Input Impedance | 4 Mohm//5.5pF each side to ground |
Input Voltage -Catagory -Differential Range -Common Mode Range -Absolute Max. Voltage(Differential or Common Mode) |
Cat III 70 Vrms and +/- 70V(DC + Peak AC)@ 1/10 700 Vrms and +/-700V(DC + Peak AC @ 1/100 700 Vrms and +/-700V(DC + Peak AC)@ 1/10 & 1/100 1000 Vrms and +/-1400V(DC + Peak AC@ 1/10 & 1/100 |
Output Voltage -Swing -Offset (typical) -Noise (typical) -Source Impedance (typical) |
+/- 7V( into 50 kohm load) <+/-5mV 0.7mVrms 50 ohm (for using 1 Mohm input system oscilloscope) |
CMMR (typical) | -80dB @ 50 Hz, -60dB @ 20kHz |
Ambient Operating Temperature | -10 to 40 degrees centigrade |
Ambient Storage Temperature | -30 to 70 degrees centigrade |
Ambient Operating Humidity | Up to 85% RH |
Ambient Storage Humidity | Up to 85% RH |
Power Requirements* | -Standard- 4 x AA Cells, 9VDC/40mA Mains Adapter (Both Included) -Options- USB Power cord Power leads |
Length of BNC Cable | 37" |
Length of Input Leads | 17" |
Dimentions | 7 1/4" x 2 3/4" x 1" |
Weight | .583 lb |
Plugs 4mm Banana plugs | - Use with accessories below |
* a. The supplied voltage must be less than 12V and greater than 4.4V, otherwize the probe could be damagedor will not operate properly.
b. polarity is "+" inside and "V" outside. For wrong polarity, built-in circuit protects the probe, no danger ordamage will occur.
c. When the voltage of the cells become too low, the power indicator on the panel wiill flicker.
Shipping and handling
Item location United States
Worldwide
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
$140.00 | NA | Expedited International Shipping |
Domestic
Shipping and handling | Each additional item | To | Service |
---|---|---|---|
$30.00 | NA | United States | Economy Shipping |
Return policy
After receiving the item, connect seller within | Refund will be given as | Return shipping |
---|---|---|
14 Days | Money Back | Buyer pays return shipping |
Payment options
Options: NA