LeCroy HRO 66Zi Oscilloscopes

Product Details

  • Manufacturer: LeCroy

  • Model: 66Zi

  • Description:

    600 MHz, 2 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display. 50 ohm and 1 Mohm Input

No Current Sellers for LeCroy 66Zi

Sign Up/Login to get notified when someone has one for sale.

600 MHz, 2 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display. 50 ohm and 1 Mohm Input

High Resolution Oscilloscopes HRO 64Zi and HRO 66Zi, 400MHz and 600MHz models

The world’s clearest and lowest-noise Oscilloscopes are the new HRO models from Teledyne LeCroy. Teledyne LeCroy’s High Resolution Oscilloscopes combine true 12-bit ADC’s and newly designed low-noise front ends to deliver unmatched signal fidelity. From the crisp, ultra-thin traces to the blazing update speed and responsiveness, Teledyne LeCroy HRO models provide a shocking contrast to traditional 8-bit oscilloscopes.

WaveRunner 6 Zi Oscilloscope Overview

Title

Video End —>Superior Validation, Debug, Analysis

Teledyne LeCroy HRO models contain a powerful feature set which includes a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.

Excellent Signal Fidelity

The Teledyne LeCroy HRO family features a pristine signal acquisition architecture that offers unmatched signal fidelity with low noise. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics.

A New Way to Navigate and View

The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.

The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.

Simply slide the button on the left side of the display and rotate upwards 90. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.

More Trigger Capability Isolates More Problems More Quickly

A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution.

Rotating Display

The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.

The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.

Rotate the screen 90 degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.

MS-500 : 500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36 : 250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option
MS-250 : 250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option
WR6Zi-HRO-L-128 : 128 Mpt/Ch Standard Memory for HRO 6Zi. Includes 4GB of RAM.
WR6Zi-HRO-XL-256 : 256 Mpt/Ch Standard Memory for HRO 6Zi. Includes 4GB of RAM.
WR6Zi-500GB-RHD-02 : Additional 500 GB Hard Drive for use with RHD option.
USB2-GPIB : External USB 2.0 to GPIB IEEE 488.2 adapter
WR6Zi-PWR : Power Analysis Option for WR 6 Zi
WR6Zi-VBA : Vehicle Bus Analyzer Bundle Includes CAN TDM, CAN Symbolic, FlexRay TDP, LIN TD and Protobus MAG.
WR6Zi-USB2bus TD : USB2 Trigger and Decode option for WaveRunner 6Zi series
WR6Zi-CAN FDbus TD : CAN FD Trigger and Decode Option for WaveRunner 6Zi series
WR6Zi-NRZbus D : NRZ Bus Decode Option for WaveRunner 6Zi series
WR6Zi-Manchesterbus D : Manchester Bus Decode Option for WaveRunner 6Zi series
WR6Zi-ENETbus D : ENET Bus Decode Option for WaveRunner 6Zi
WR6Zi-DigRFV4bus D : DigRF V4 Bus Decode option for WaveRunner 6Zi series
WR6Zi-ARINCbus Dsymbolic : ARINC 429 Bus Symbolic Decode option for WaveRunner 6Zi series
WR6Zi-I2Cbus TD : I2C Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-SPIbus TD : SPI Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-UART-RS232bus TD : UART and RS232 Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-CANbus TD : CAN Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-CANbus TDM : CAN Bus Trigger, Decode & Measure/Graph Option for WaveRunner 6Zi series
WR6Zi-FlexrayBus TD : FlexRay Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-FlexRayBus TDP : FlexRay Bus Trigger, Decode, and Physical Layer Test Option for WaveRunner 6Zi series
WR6Zi-CAN FDbus TDM : CAN FDbus Trigger, Decode & Measure/Graph Option for WaveRunner 6Zi series
WR6Zi-SpaceWirebus D : SpaceWire Decode Option for WaveRunner 6Zi series
WR6Zi-LINbus TD : LIN Bus Trigger & Decode Option for WaveRunner 6Zi series
WR6Zi-1553 TD : MIL-STD-1553 Trigger and decode option for WaveRunner 6Zi series
WR6Zi-AudioBus TD : AudioBus Trigger and Decode option for WaveRunner 6Zi series
WR6Zi-AudioBus TDG : AudioBus trigger, decode, and graph option for WaveRunner 6Zi series
WR6Zi-USB2bus TD : USB2 Trigger and Decode option for WaveRunner 6Zi series
WR6Zi-DigRF3Gbus D : DigRF 3G Bus Decode option for WaveRunner 6Zi series
WR6Zi-CANbus TDM SYMBOLIC : CANbus Trigger, Symbolic Decode & Measure/Graph Option for WaveRunner 6Zi series
WR6Zi-CAN FDbus TDM SYMBOLIC : CAN FDbus Trigger, Symbolic Decode & Measure/Graph Option for WaveRunner 6Zi series
WR6Zi-DPHYbus D : MIPI D-PHY CSI-2, DSI Bus Decode option for WaveRunner 6Zi series
WR6Zi-ProtoBus MAG : Serial Debug Toolkit – Measure Analyze Graph for WaveRunner 6Zi series. Compatible with I2C, SPI, UART, CAN, LIN, FLX, D-PHY, DigRF 3G, DigRF v4, ARINC 429, MIL-STD-1553
WR6Zi-EMB : Embedded bundle, Includes I2C TD, SPI TD, UART-RS232 TD
WR6Zi-MSO-EMB : Embedded bundle, Includes MS-500-36 with I2C TD, SPI TD, UART TD
WR6Zi-DPHYbus D : MIPI D-PHY CSI-2, DSI Bus Decode option for WaveRunner 6Zi series
WR6Zi-DPHYbus DP : MIPI D-PHY CSI-2, DSI Bus Decode and Physical Layer test option for WaveRunner 6Zi series
WR6Zi-MPHYbus D : MIPI M-PHY Bus Decode Option for WaveRunner 6Zi series
WR6Zi-MPHYbus DP : MIPI M-PHY Bus Decode and Physical Layer test Option for WaveRunner 6Zi series
WR6ZI-SENTbus D : SENT Bus Decode Option for WaveRunner 6Zi series
WR6Zi-JITKIT : Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay
WR6Zi-DFP2 : Digital Filter Software Package for WaveRunner 6Zi Series
WR6Zi-SDM : Serial Data Mask Software Package for WaveRunner 6Zi Series
WR6Zi-XDEV : Developer’s Tool Kit Option for WaveRunner Series
WR6Zi-SPECTRUM : Spectrum Analyzer and Advanced FFT Option for WaveRunner 6Zi Series
WR6Zi-EMC : EMC Pulse Parameter Software Package for WaveRunner 6Zi Series
WR6Zi-ET-PMT : Electrical Telecom Pulse Mask Test Package for WaveRunner 6Zi Series
KYBD-1 : Keyboard, USB
WR6Zi-HARDCASE : WaveRunner 6Zi Hard Carrying Case
WR6Zi-RACK : Rack-mount accessory for converting a WaveRunner 6Zi series oscilloscope to an 8U rack-mounted package
WR6Zi-ExtRef-IN/OUT : External Adaptor for Reference In and Out. To be applied at the Lbus connector
WR6Zi-Cover : WaveRunner 6Zi Protective Front Cover
OC1024-A : Instrument Cart with additional shelf and drawer
OC1021-A : Instrument Cart
WR6Zi-Pouch : WaveRunner 6Zi Accessory pouch. Includes mounting bracket.
WR6Zi-Softcase : WaveRunner 6Zi Soft Carrying Case
WR6ZI-8CH-SYNCH : 8ch synch capability to combine 2 WR6Zi oscilloscopes
WR6Zi-DDM2 : Disk Drive Measurements Software Package for WaveRunner 6Zi Series
WR6Zi-DDA : Disk drive analyzer software package for WaveRunner 6Zi series
WR6Zi-AORM : Advanced Optical Recording Measurement Package for WaveRunner Series
PK400-0 : Extra Large Gripper Probe Set . Includes 22 probes
PK400-1 : Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads
PK400-2 : Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads
PK400-3 : Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads
MSO-MICTOR : 36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD)
MSO-3M : 18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002)
MSO-DLS-36 : 16" Digital Lead Set, D18-D35